The foreword and administration provides a brief history of the development of the NCS and the process for its future evolution and development. The following are sample pages from each module of the standard (Adobe Acrobat PDFs): Foreword and Administration The United States National CAD Standard (NCS) version 6 is comprised of the Foreword, Administration, AIA CAD Layer Guidelines, Uniform Drawing System, BIM Implementation, Plotting Guidelines and Appendixes. Implementation of the NCS eliminates overhead costs that many organizations now incur trying to maintain proprietary office standards, training new staff in their use, and coordinating proprietary office formats among various design consultants. Adoption will benefit architects, engineers, contractors, and building owners by establishing a common language for the building design and documentation process. Voluntary adoption of the Standard across the industry will improve the efficiency of building design, construction, and management throughout the life-cycle of facilities.
![proprietary notes for fire sprinkler system design drawings proprietary notes for fire sprinkler system design drawings](https://fiverr-res.cloudinary.com/images/q_auto,f_auto/gigs2/146733277/original/047b59aede30a09e430561a16a8d779daee9f973/do-fire-protection-sprinkler-system-design-drafting.jpg)
#PROPRIETARY NOTES FOR FIRE SPRINKLER SYSTEM DESIGN DRAWINGS MANUAL#
The flow test results are compared with the design calculations to ensure full compliance with the design and the relevant standards.įollowing commissioning the design engineers will provide ‘as fitted’ drawings, which will form part of the O&M manual and/or user’s guide.Home / Version 6 Content United States National CAD Standard® Content On completion of the installation, system commissioning will be carried out including a full flow test. If any deviations from the design drawings are required during installation, these are noted and forwarded to the design engineers who will make any adjustments that may be required. After approval, a design document will be prepared and forwarded whilst working drawings will be prepared for use by the installation engineers. The design drawings will then be forwarded to the client for approval. Any problematic areas will be discussed with the client to come up with a solution that satisfies both the British Standard and that of the client’s wishes. Our design engineers will, as far as possible, line up the fire sprinklers with the lighting plan. Normally the drawings supplied to us will include the lighting layout for the property. The system water requirements will be noted on the design document. This ensures that all the sprinkler heads in the system will perform in accordance with the British Standard and that the design is the most cost efficient. The sprinkler pipe network is then balanced by changing pipe diameters. This will determine the water flow and pressure required by the system. The sprinkler system pipe work is then added to connect the fire sprinkler heads to the supply, which will either be a direct water supply from an incoming mains pipe or a water storage tank with a fire pump set.įull Hydraulic Calculations, (FHC), are then carried out using Canute software.
![proprietary notes for fire sprinkler system design drawings proprietary notes for fire sprinkler system design drawings](http://www.meyerfire.com/uploads/1/6/0/7/16072416/comparison-500x500_orig.jpg)
On receipt of suitable drawings of the building to be protected, the design engineers will start by adding fire sprinkler heads in accordance with the requirements of BS9251 and manufacturers recommendations. Designing the Sprinkler System for the BuildingĪll our designs take into account BS9251 and any other relevant technical/guidance documents. This process can take as little as a few hours to several weeks, depending on the size and complexity of the building.
#PROPRIETARY NOTES FOR FIRE SPRINKLER SYSTEM DESIGN DRAWINGS SOFTWARE#
Then the pipe routes need to be worked out along with the diameter of the pipes.Īll this information is fed into software programs where fine tuning is carried to ensure compliance with the relevant standards. Each sprinkler head must be positioned to ensure that the protected room is covered correctly as well as being sympathetic to the visual look of the ceiling as a whole. The design of a residential sprinkler system is more demanding than it first appears.